Vendors

  • With a low pressure drip and excellent sealing, dual-plate check valves prevent the risk of backflow in liquid and gas lines.
  • The swing-plate check valve is a cost-effective way to prevent backflow in your pipelines and other industrial applications for use with a wide range of fluids such as gases, liquids and steams.
  • Benchmark Measurement Solutions is proud to present the CF-200 Algae Monitor. Using the C-Fluor fluorescence probe, the online monitor is fully integrated and ready to detect Chlorophyll A in fresh or sea water.
  • The Sentry Cobra C manual gas sampler collects representative samples from gas and liquid short-chain hydrocarbon applications. This emission-free sampler uses a multi-ported valve. This valve simplifies the process of taking a sample. Additionally, it keeps the sample's integrity and handles environmental risks.
  • The Sentry Cobra DT closed loop sampler is designed to perform a detector tube measurement as safely, quickly and efficiently as possible. The Cobra DT sampler is designed with safety in mind, with a high-pressure regulator providing operators with a means to lower pressure to a safe level before inserting the detector tube. The 1000 cc cylinder allows a large volume of gas to be chambered so the operator can draw a fresh sample through the detector tube allowing a representative measurement to be collected.
  • The Sentry Cobra SS manual liquid sampler allows for safe and straightforward petroleum and natural gas sampling. The sampler design ensures a representative sample through direct connections to your lines. This Sentry low-emission sampler stands up to water corrosion and meets the highest quality and reliability standards required of petroleum sampling equipment.
  • Save energy and control your cooling-water return temperature with GESTRA's self-acting mechanical control valve CW (GESTRAMAT). GESTRA's CW cooling-water control valves (GESTRAMAT) help you to save energy by reducing the cooling-water flow to a minimum, and keeping the discharge temperature to the maximum permissible value. These control valves are self-acting and sense the discharge temperature by the integral regulator, so you can reduce operating costs.
  • Suitability-tested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process gas in pipes or ducts.
  • Suitability tested and certified ultrasonic measuring system to measure the velocity and the volume flow of flue gas or process gas in pipes or ducts, especially for wet and aggressive smoke emissions.
  • Measuring system for continuous evaluation of flow velocity and flow direction in tunnels. Ultrasonic sensors for tunnel ventilation control system. Reliable measurement across the tunnel profile. Two identical sensors alternately transmit and receive ultrasonic pulses. The system evaluates the transition times dependent on direction and calculates flow speed. D-FL 220T requires extremely low maintenance.
  • Digital Furnace Camera delivers brilliant live video directly out of the combustion chamber. Available in air or water cooled versions for process temperatures up to 2000°C. The D-FS 50 can be combined with the D-VT 50 Video System or the D-VTA 200 Thermography Analysis System.
  • The digital furnace sensor D-FS2 delivers high definition live images directly out of the combustion chamber. The D-FS2 VIS with high resolution colour video is available as water or air cooled version. The furnace sensor D-FS2 is designed for the use with a retraction unit. All versions can be extended with the D-VTA 200 software to a thermography and analysis system.
  • Flame sensor (flame scanner) for the monitoring of gas and oil flames, primarily in gas turbines or in particularly harsh environments.
  • Flame sensor (flame scanner) for the monitoring of gas, oil and coal flames, primarily in single burner view applications.
  • The installation of fibre optic systems is recommended if it is not possible to place the flame monitor at an optimal position in order to guarantee best and permanent flame monitoring. A fibre optic system is also useful if the conditions of the environment are harsh to electronic devices.
  • Self-monitoring and fail-safe compact flame monitor for the monitoring of gas, oil and coal flames with integrated UV, VIS or IR flame sensor, primarily in single burner view applications.
  • Compact and cost effective transmittance dust and opacity measuring device for monitoring medium to high dust concentrations in dry flue and process gas.
  • The Sentry W7950 sparger assembly is used to prepare a sample for taking a degassed cation conductivity measurement.
  • Compact thermodynamic steam traps are ideal for draining heating processes with small load fluctuations, including saturated and superheated steam systems, steam tracing, and air heaters.
  • Sentry DPA Series offers easy-to-use drip pot assemblies to collect samples within a pipeline or other pressurized system for the purpose of examining and measuring corrosion products and other contaminants, without interruption to the system. Drip pot assemblies collect the samples for analysis using a container with an interior reservoir for receiving a liquid sample, and a valve assembly coupled to the drip pot.
  • Sentry DTC (dual tube coil) tube-in-tube heat exchangers are spirally wound, full counter flow heat exchangers well suited for a variety of applications where low flow rates of high temperature and/or high pressure fluids need cooling or heating. The sturdy tube-within-a-tube concept uses heavy duty terminal fittings to provide for a plain tube end interface for the inner tube, and a compression connection for the outer tube.
  • Ambient air particulate monitor to detect TSP, PM10 or PM2.5 in ambient air for use in industrial or governmental ambient air monitoring networks.
  • A flame front generator is a system in which a gas/air mixture is introduced at ground level and flows up a one-inch line to the pilot burner. After filling this line with the mixture it is ignited by a spark. The resulting flame travels to the top of the flare where the pilot burner is ignited.
  • Ignition of waste gas from pipe flares, air and steam assisted flares and ground flares. For most flare systems the pilot burner can not be accessed for service. Maintenance or replacement is not possible while the flare is in operation. To safeguard operation, Smitsvonk’s pilots provide reliable ignition and stable burning even under the most difficult climate conditions. Flame front ignition version of this product is also available
  • A gas fired igniter boasting compact design with an integrated spark transformer and ionization flame monitor/burner control, a convenient and built in flame rod, guaranteed electromagnetic compatibility, and a rugged low maintenance design that does not require an on-site high voltage cable. Igniters are made in sizes ranging from 2 kW to 10 MW (7000 BTU/hr to 35000000 BTU/hr), and fuel types are tailored to customer preference and analysis.
  • A gas burner boasting a rugged and low-maintenance design with guaranteed electromagnetic compatibility, easy-to-replace electrical components, built-in convenient flame rod, and does not require on-site high-voltage cables. Fuel types include natural gas, conditioned coke over gas, propane, butane, or process gas according to customer preference.
  • Orbital is a customized solutions provider. Orbital’s design engineers will work alongside you to develop an analytical system that perfectly fits your needs. GasPT, or "Gas Properties Transmitter," is an online analyzer that provides the following physical properties of natural gas:
    • Calorific Value (CV) / British Thermal Unit (BTU)
    • Wobbe Index (WI)
    • Relative Density (RD)
    • Compression Factor (Z)
    • Methane Number (MN)
    • Total Air Requirements (TAR)
    • MON
    • SOS
  • GESTRA's GCV general-purpose control valves are engineered to provide solutions for steam, condensate, and other industrial fluid, as well as gas applications and processes. These general-purpose control valves reliably and precisely control temperature and pressure within your processes. GCV valves are available with electric or pneumatic actuator, positioners, and compressed air filter/regulators.
  • Ignition lance with high voltage cable, guided in a metal hose, for hazardous areas according NEC 500. This design boasts flexible customization for specific installation conditions as well as easily replaceable ignition tips which are specialized for ignition of HFO or at high pressure.
  • InSight is designed for high pressure combustible gas systems. It will be able to safely access systems via existing tapping points and become a versatile tool to perform a number of tasks that currently require a plant shutdown. InSight will have the ability to investigate the internal condition of piping and pressure vessels Additional tools will enable operators to troubleshoot operations problems such as foaming or fouling.

  • The Sentry ISOLOK SAL-DBB automatic point sampler collects representative liquid and slurry samples in harsh operating conditions, such as oil sand mining. Safety, reliability, convenience and ease of service are all designed into this sampler, which features patented double block and bleed technology.
  • The Sentry ISOLOK SAL-Q automatic point sampler is a heavy-duty, isolatable sampler using ISOLOK proven technology and suitable for oil sands and other mining applications. The Sentry ISOLOK SAL-Q sampler employs the industry-proven Delta double block and bleed, ANSI-rated knife gate valve to isolate the sampler from the process line when the sampler needs servicing.  
  • LineVu reveals contamination in high pressure natural gas systems that until now has been un-detected. Despite commercial and legal contracts requiring that no liquids or solids should enter a gas network, it is common to find that liquid contamination is the cause of damage to power stations and other plant all over the world.
  • The Packing Leak Detector (PLD) helps reduce leak rates to near zero. Methane leaks from compressor packing glands are common and result in lost revenue and can lead to environmental penalties. The PLD provides mechanical or digital notification of a leak allowing for early intervention and remedy.
  • The MAX100-BTU provides a rapid, high precision measurement of heating value and gas composition for optimal combustion control and environmental compliance.
    The MAX100-BTU uses cutting-edge quadrupole mass spectrometer technology to deliver a continuous online analysis of fuel gas and vent streams containing hydrocarbons, H2, CO, CO2, H2O, H2S and other gases. It has the speed necessary to analyze the total composition of the sample and report the Heating Value in seconds.
  • The MAX300-AIR is an industrial gas analyzer optimized for environmental and ambient air monitoring and regulatory compliance. Quadrupole mass spectrometry is extremely sensitive and very fast, allowing for the rapid detection and quantitation of a wide variety of toxic industrial contaminants. The speed of the MAX300-AIR allows one analyzer to measure unlimited compounds and be automated to monitor 160+ sample points, spread throughout the manufacturing site.
Go to Top