Mustang Sampling

Pony® Sample Conditioning System

The Pony® Sample Conditioning System (PSCS®) is ideal for sampling wet or dry natural gas when a compact solution mounted directly to the sampling probe is preferred. The PSCS contains a self-limiting block heater, Watlow® PID temperature controller, system temperature limiter, and a single or multistage pressure regulator, all mounted inside a Pony® Heated Probe Enclosure. The close coupled system reduces the opportunity for richer gases to condense within sample tubing and protects analyzers from damage by solids or liquids while delivering a representative sample

Description

The Pony® Sample Conditioning System (PSCS®) is ideal for sampling wet or dry natural gas when a compact solution mounted directly to the sampling probe is preferred. The PSCS contains a self-limiting block heater, Watlow® PID temperature controller, system temperature limiter, and a single or multistage pressure regulator, all mounted inside a Pony® Heated Probe Enclosure. The close coupled system reduces the opportunity for richer gases to condense within sample tubing and protects analyzers from damage by solids or liquids while delivering a representative sample. The Pony® Sample Conditioning System is the only probe mounted sample conditioning system that can be powered by the heat trace tube bundle, creating a cost effective solution for new or existing locations.


Features

  • Patented technology utilizing existing power supplied by heat trace tube bundle
  • Molded narrow clam shell design
  • Rated for Class 1, Division 1, Group D Locations
  • Compatible with Mustang CertiSeries® line of products
  • Steel latching closures

Benefits

  • Requires no external power or natural gas for proper operation
  • Conforms to API 14.1 guidelines for hydrocarbon liquid removal and heat tracing
  • Protects probes from temperature and weather fluctuations
  • Helps preserve sample integrity
  • Prevents Joule-Thomson cooling
  • Direct-mount on pipeline fitting between 6” center-tocenter threadolets (TOLs)
  • Fits over existing probe brands
  • Closely coupled to the sample point

Specifications

Maximum allowable operating pressure MHR® Single-Stage Regulator
3750 psig (259 BAR) @ 60ºF (16ºC)
MJTHR® Multi-Stage Regulator
6000 psig (408 BAR) @ 60ºF (16ºC)
Wetted parts 316 SS Nace Compliant
Regulator sample volume/Cv 0.51 cu. in.
Regulator Cv 0.023
Regulator Options MHR® Single-Stage Regulator
MJTHR® Multi-Stage Regulator
Input Supply Voltage Options 120 VAC, 215 Watts, 50/60 Hz, ± 10%
240 VAC, 215 Watts, 50/60 Hz, ± 10%
24 VDC, 155 Watts
PID Temperature Controller Options OI Oven Industries Controller
W Watlow® Controller
Cabinet Construction Options GPR Hotpressed Glass Fiber Reinforced Polyester
SS Stainless Steel