Chemical Injection Pumps and Controllers
- TXAM Pumps manufactures and sells chemical injection pumps for a wide range of applications in the Oil and Gas industry.
- They offer a full line of Solar & AC pumps as well as Class 1, Division 2 options for hazardous areas.
- TXAM Pumps also offers Beam and Pneumatic Pumps to meet your Chemical Injection needs.
- They manufacture multi-point chemical injection systems that allow you to control multiple injection points with a single pump.
- Designed to meet your specific needs, we can provide chemical injection for up to 16 points, all controlled remotely through their UPC or TSP600N Controllers.
Products
-
A gas fired igniter boasting compact design with an integrated spark transformer and ionization flame monitor/burner control, a convenient and built in flame rod, guaranteed electromagnetic compatibility, and a rugged low maintenance design that does not require an on-site high voltage cable. Igniters are made in sizes ranging from 2 kW to 10 MW (7000 BTU/hr to 35000000 BTU/hr), and fuel types are tailored to customer preference and analysis.
-
A gas burner boasting a rugged and low-maintenance design with guaranteed electromagnetic compatibility, easy-to-replace electrical components, built-in convenient flame rod, and does not require on-site high-voltage cables. Fuel types include natural gas, conditioned coke over gas, propane, butane, or process gas according to customer preference.
-
Orbital is a customized solutions provider. Orbital’s design engineers will work alongside you to develop an analytical system that perfectly fits your needs. GasPT, or "Gas Properties Transmitter," is an online analyzer that provides the following physical properties of natural gas:
- Calorific Value (CV) / British Thermal Unit (BTU)
- Wobbe Index (WI)
- Relative Density (RD)
- Compression Factor (Z)
- Methane Number (MN)
- Total Air Requirements (TAR)
- MON
- SOS
-
GESTRA's GCV general-purpose control valves are engineered to provide solutions for steam, condensate, and other industrial fluid, as well as gas applications and processes. These general-purpose control valves reliably and precisely control temperature and pressure within your processes. GCV valves are available with electric or pneumatic actuator, positioners, and compressed air filter/regulators.
-
Ignition lance with high voltage cable, guided in a metal hose, for hazardous areas according NEC 500. This design boasts flexible customization for specific installation conditions as well as easily replaceable ignition tips which are specialized for ignition of HFO or at high pressure.
-
InSight is designed for high pressure combustible gas systems. It will be able to safely access systems via existing tapping points and become a versatile tool to perform a number of tasks that currently require a plant shutdown. InSight will have the ability to investigate the internal condition of piping and pressure vessels Additional tools will enable operators to troubleshoot operations problems such as foaming or fouling.
-
The Sentry ISOLOK SAL-DBB automatic point sampler collects representative liquid and slurry samples in harsh operating conditions, such as oil sand mining. Safety, reliability, convenience and ease of service are all designed into this sampler, which features patented double block and bleed technology.
-
The Sentry ISOLOK SAL-Q automatic point sampler is a heavy-duty, isolatable sampler using ISOLOK proven technology and suitable for oil sands and other mining applications. The Sentry ISOLOK SAL-Q sampler employs the industry-proven Delta double block and bleed, ANSI-rated knife gate valve to isolate the sampler from the process line when the sampler needs servicing.
-
The J22 Gas Analyzer uses patented tunable diode laser absorption spectroscopy (TDLAS) technology to provide accurate measurement of H2O in natural gas. Featuring the reliable diagnostic capabilities of Heartbeat Technology, the J22 analyzer determines the concentration of a gas without coming into physical contact with streams. It allows pipeline operators and suppliers to meet quality specifications, prevent pipeline corrosion, and stop hydrate formation to ensure safety and asset integrity.
-
LineVu reveals contamination in high pressure natural gas systems that until now has been un-detected. Despite commercial and legal contracts requiring that no liquids or solids should enter a gas network, it is common to find that liquid contamination is the cause of damage to power stations and other plant all over the world.
-
The Packing Leak Detector (PLD) helps reduce leak rates to near zero. Methane leaks from compressor packing glands are common and result in lost revenue and can lead to environmental penalties. The PLD provides mechanical or digital notification of a leak allowing for early intervention and remedy.
-
The MAX100-BTU provides a rapid, high precision measurement of heating value and gas composition for optimal combustion control and environmental compliance.The MAX100-BTU uses cutting-edge quadrupole mass spectrometer technology to deliver a continuous online analysis of fuel gas and vent streams containing hydrocarbons, H2, CO, CO2, H2O, H2S and other gases. It has the speed necessary to analyze the total composition of the sample and report the Heating Value in seconds.
-
A gas fired igniter boasting compact design with an integrated spark transformer and ionization flame monitor/burner control, a convenient and built in flame rod, guaranteed electromagnetic compatibility, and a rugged low maintenance design that does not require an on-site high voltage cable. Igniters are made in sizes ranging from 2 kW to 10 MW (7000 BTU/hr to 35000000 BTU/hr), and fuel types are tailored to customer preference and analysis.
-
A gas burner boasting a rugged and low-maintenance design with guaranteed electromagnetic compatibility, easy-to-replace electrical components, built-in convenient flame rod, and does not require on-site high-voltage cables. Fuel types include natural gas, conditioned coke over gas, propane, butane, or process gas according to customer preference.
-
Orbital is a customized solutions provider. Orbital’s design engineers will work alongside you to develop an analytical system that perfectly fits your needs. GasPT, or "Gas Properties Transmitter," is an online analyzer that provides the following physical properties of natural gas:
- Calorific Value (CV) / British Thermal Unit (BTU)
- Wobbe Index (WI)
- Relative Density (RD)
- Compression Factor (Z)
- Methane Number (MN)
- Total Air Requirements (TAR)
- MON
- SOS
-
GESTRA's GCV general-purpose control valves are engineered to provide solutions for steam, condensate, and other industrial fluid, as well as gas applications and processes. These general-purpose control valves reliably and precisely control temperature and pressure within your processes. GCV valves are available with electric or pneumatic actuator, positioners, and compressed air filter/regulators.
-
Ignition lance with high voltage cable, guided in a metal hose, for hazardous areas according NEC 500. This design boasts flexible customization for specific installation conditions as well as easily replaceable ignition tips which are specialized for ignition of HFO or at high pressure.
-
InSight is designed for high pressure combustible gas systems. It will be able to safely access systems via existing tapping points and become a versatile tool to perform a number of tasks that currently require a plant shutdown. InSight will have the ability to investigate the internal condition of piping and pressure vessels Additional tools will enable operators to troubleshoot operations problems such as foaming or fouling.
-
The Sentry ISOLOK SAL-DBB automatic point sampler collects representative liquid and slurry samples in harsh operating conditions, such as oil sand mining. Safety, reliability, convenience and ease of service are all designed into this sampler, which features patented double block and bleed technology.
-
The Sentry ISOLOK SAL-Q automatic point sampler is a heavy-duty, isolatable sampler using ISOLOK proven technology and suitable for oil sands and other mining applications. The Sentry ISOLOK SAL-Q sampler employs the industry-proven Delta double block and bleed, ANSI-rated knife gate valve to isolate the sampler from the process line when the sampler needs servicing.
-
The J22 Gas Analyzer uses patented tunable diode laser absorption spectroscopy (TDLAS) technology to provide accurate measurement of H2O in natural gas. Featuring the reliable diagnostic capabilities of Heartbeat Technology, the J22 analyzer determines the concentration of a gas without coming into physical contact with streams. It allows pipeline operators and suppliers to meet quality specifications, prevent pipeline corrosion, and stop hydrate formation to ensure safety and asset integrity.
-
LineVu reveals contamination in high pressure natural gas systems that until now has been un-detected. Despite commercial and legal contracts requiring that no liquids or solids should enter a gas network, it is common to find that liquid contamination is the cause of damage to power stations and other plant all over the world.
-
The Packing Leak Detector (PLD) helps reduce leak rates to near zero. Methane leaks from compressor packing glands are common and result in lost revenue and can lead to environmental penalties. The PLD provides mechanical or digital notification of a leak allowing for early intervention and remedy.
-
The MAX100-BTU provides a rapid, high precision measurement of heating value and gas composition for optimal combustion control and environmental compliance.The MAX100-BTU uses cutting-edge quadrupole mass spectrometer technology to deliver a continuous online analysis of fuel gas and vent streams containing hydrocarbons, H2, CO, CO2, H2O, H2S and other gases. It has the speed necessary to analyze the total composition of the sample and report the Heating Value in seconds.