Sentry Equipment

TSV Thermal Shutoff Valve

The Sentry TSV is a self-contained, mechanical device that protects operators, analyzers and sampling components from high temperature liquids. It is an economical and reliable mechanical replacement for a solenoid shutoff valve and temperature controller, requiring no external source of electricity, air or hydraulics.

Description

Description

The Sentry TSV is a self-contained, mechanical device that protects operators, analyzers and sampling components from high temperature liquids. It is an economical and reliable mechanical replacement for a solenoid shutoff valve and temperature controller, requiring no external source of electricity, air or hydraulics.

The sensor/actuator is directly exposed to the sample medium. High temperatures actuate the device in less than five seconds. Some of the causes of high temperatures include loss of cooling water, insufficient cooling water pressure or flow, high cooling water temperature, high sample flow rate, a ruptured coil in the sampler cooler, or a fouled or plugged sample cooler.

A reliable mechanical solution that requires no electricity to operate, the Sentry TSV provides positive closure. It must be manually reset after a trip, which ensures that sample flow is not resumed before the cause of the system upset has been corrected.

The Sentry TSV should be installed downstream of the pressure-reducing device and upstream of analyzers, flowmeters and other low-pressure devices. After a trip, the upstream side of the Sentry TSV will be exposed to the full source pressure. A red indicator readily provides visual indication of valve position, and an optional switch is available to provide a signal for a remote alarm.


Benefits

  • Protects operators and equipment
  • Suitable for system pressures up to 4400 psig (303 barg)
  • Flow shutdown in less than five seconds
  • Completely mechanical design requires no electricity, air or hydraulics
  • Push-button reset
  • Optional dry contact for remote alarm indication
  • Visual trip indication

Features

More Information
Standards CRN
Max Process Pressure 4400 psig (303 barg)
Process Temperature 250°F (121°C)
Process Connections 1/4 in OD Tube
Wetted Materials 316 SS, Viton, PEEK

Resources

Sentry TSV Thermal Shutoff Valve Specification Sheet

Additional information

Trip Temperature

95°F (35°C), 104°F (40°C), 109°F (43°C), 120°F (43°C), 131°F (55°C), 140°F (60°C), 153°F (67°C), 160°F (71°C), 194°F (90°F), 203°F (95°C)

Title

Go to Top