Call us : 1.866.416.0516

Call us : 1.866.416.0516

SpectraSensors

SS2000 Single Channel Analyzer

SpectraSensors SS2000 Single Channel Analyzer for H2O or CO2 is extremely reliable and tailored for the needs of the natural gas industry. The sensor measures gas using a patented Tunable Diode Laser (TDL) to determine the concentration of the gas without coming into physical contact with the stream.

Category:

Description

SpectraSensors SS2000 Single Channel Analyzer for H2O or CO2 is extremely reliable and tailored for the needs of the natural gas industry. The sensor measures gas using a patented Tunable Diode Laser (TDL) to determine the concentration of the gas without coming into physical contact with the stream.

Rapid Response Time

The SS2000 analyzer takes four measurements per second with a laser and detector and immediately averages the results. Because there is no contact with the gas, real-time measurements are not hampered by wet-up or dry-down times as with surfaced-based sensors.

Reliable

Trustworthy measurements are vital to natural gas pipeline and processing companies. Independent studies have proven that the SS2000 results are highly correlated with those of chilled mirrors. However, chilled mirrors require skilled experts to operate and the results are highly scattered (large standard deviation).

Uncertain measurements can be extremely costly. Additional processing of dehydration costs, upset conditions, shut-ins and inconsistent process results may be caused by sensors that do not perform properly. The SS2000 is the first to offer truly reliable measurement and simple operation.

Long Life

The TDL sensor does not come into contact with the sample gas stream. The result is a sensor which does not suffer from contamination or drift due to vapor impurities such as glycol, methanol or amines.

Low Cost of Ownership

Operating costs are significantly reduced by eliminating the cost of consumables, extra sensor heads, labor and overhead associated with excessive maintenance.

The SS2000 dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data.


Manuals

 SS500/SS2000 Hardware Installation and Maintenance Manual

 SS500XP/SS2000XP Hardware Installation/Maintenance Manual

 Firmware v2.51 Operator’s Manual

 SCS Remote Panel Manual


Resources

Class 1, Div. 2 package
icon-pdf.png Data Sheet
icon-pdf.png Technical Information
icon-pdf.png Analyzer System Drawings
Class 1, Div. 1 package
icon-pdf.png Data Sheet
icon-pdf.png Drawings

 

 

 


 

Go to Top