Extrel

MAX300-BIO Bioreactor Gas Analyzer

Fast, Accurate, Efficient

Mass Spectrometry is a powerful tool for bioreactor monitoring. Changes to the composition of bioreactor or fermentor off-gas provide crucial insight into cellular health and production efficiency. This makes the fast, accurate analysis of CO2, O2, N2, Ar, H2O and other compounds essential for real-time process control.

The MAX300-BIO uses cutting edge quadrupole mass spectrometer technology to quantify bioreactor gases from multiple reactors within the facility and reports the data to the control system in real-time.

Description

Description

Fast, Accurate, Efficient

Mass Spectrometry is a powerful tool for bioreactor monitoring. Changes to the composition of bioreactor or fermentor off-gas provide crucial insight into cellular health and production efficiency. This makes the fast, accurate analysis of CO2, O2, N2, Ar, H2O and other compounds essential for real-time process control.

The MAX300-BIO uses cutting edge quadrupole mass spectrometer technology to quantify bioreactor gases from multiple reactors within the facility and reports the data to the control system in real-time.


OVERVIEW

  • Measures CO2, O2, N2, H2O, alcohols, contaminants, and more
  • Samples without risk of contamination
  • Calculates control parameters in real-time (e.g. Respiratory Quotient)
  • Provides flow and mass balance data
  • Multiport sample systems for up to 80+ reactors
  • High precision and accuracy for optimal process automation
  • Low maintenance, utilities and calibration required
  • Complete method scale-up
  • Lab, Pilot, Production

SYSTEM SPECS

Mass Range Options

  • 1-250, 300, 500 amu

Detectable Compounds

  • Any gas or vapor sample

Detection Range

  • 100% – 10 ppm standard, 10 ppb with the electron multiplier option*

Number of Sample Streams

  • 16, 31, 40 or 80+

Analysis Rate

  • <0.4 seconds per component

Number of Components

  • Unlimited

Number of Analysis Routines

  • Unlimited

Number of User Configurable Data Tags

  • Unlimited

Analysis Precision

  • <0.25% Relative Standard Deviation**

Stability

  • <0.5% Relative Standard Deviation over 30 days**

Filaments

  • Two, one active and one spare with automatic switchover

Maintenance

  • Typically two PMs per year

Manual or fully automated calibration and validation

*Matrix dependent. Documented on trace benzene in air

**Based on the analysis of 1% argon


Product Notes